    Performance testing and economy evaluation of induced draft fan transition to turbinedriven mode
    DU Yaqin1,YANG Xueping1,WANG Yin2
    2015, 37(3):  1-4. 
    Asbtract ( 296 )  
    Related Articles | Metrics
    Abstract:After installing denitration equipment to a super critical 630MW unit of a power plant, resistance in airgas system was increased. Therefore, the induced draft fan got transformed form motordriven mode to steam driven mode. The paper introduced smallscale turbine thermal cycle system of reformed induced draft fan and the respective performance experiment, analyzed the internal efficiency of small turbine under different load levels. After the reformation, the whole system is sable and safe, with working capability enhanced. In this way, the electricity and coal consumption of the plant can be largely reduced, while the grid power and annual revenue will rise.
    Reformation of merging induced draft fan and booster fan in one for a 600MW unit
    WANG Shouyang
    2015, 37(3):  5-6. 
    Asbtract ( 306 )  
    Related Articles | Metrics
    Abstract:In Hunan Huadian Changsha Power Generation Company Limited, in order to improve the fan operation efficiency, to reduce the fan’s power consumption and to reduce the maintenance cost, the reformation of merging the boiler induced draft fan and the desulphurization booster fan in one was carried out. The concrete content of the reformation was introduced. The hot test after reformation shows that the new induced draft fan can operate safely and stably under various conditions, and the station service power consumption rate was reduced greatly.
    Control strategy of booster fan of 680MW unit after flue gas bypass was cancelled
    TAO Liwei
    2015, 37(3):  7-9. 
    Asbtract ( 315 )  
    Related Articles | Metrics
    Abstract:Taking the 2×680MW ultra supercritical unit as example, the operation mode of the booster fan and the induced draft fan after the flue gas bypass was cancelled was introduced. The influence of operation stability of the booster fan on operation reliability of the unit was expounded. The optimized control strategy was given, and the stable operation of the unit was ensured.
    Application of improved entropy fuzzy clustering in power plant desulfurization system
    YANG Guobin1, XIE Xiangyang1, XIE Yafei2
    2015, 37(3):  10-13. 
    Asbtract ( 346 )  
    Related Articles | Metrics
    Abstract:Limestonegypsum wet FGD technology, lime or limestone as the desulfurizer, is mainly affected by raw limestone, unit’s running parameters and adjustable parameters. After reduction of the parameters, constrain adjustable parameters as slurry density, the pH value of the slurry and the calcium to sulfur ratio (Ca/S) within the optimal range of values, and the factors affecting the desulfurization efficiency are concluded as unit load, inlet SO2 concentration and slurry pump operating units. Threshold variable metric entropy fuzzy clustering (EFC) algorithm is proposed on base of the basic EFC, and its reliability is verified. The proposed algorithm is used for multiparameters’clustering on actual data within several typical load neighborhoods, to dig out the relationship between the inlet SO2 concentration, slurry pumps and the desulfurization efficiency according to different loads, furthermore, propose slurry circulating pump optimization scheduling scheme.
    Analysis on factors influencing on economic efficiency of natural gas power generation
    LIU Zhanli
    2015, 37(3):  14-17. 
    Asbtract ( 363 )  
    Related Articles | Metrics
    Abstract:Under the impact of the natural gas price, the feedin tariff and other factors, the natural gas power generation has not sufficient competitiveness. In our country, the current ongrid price of the gas power generation is the temporary ongrid price, which does not reflect the scarce resource, the environmental value and other external costs. The influences of the natural gas price and annual utilization hours on the economic efficiency of gas power generation were analyzed. Considering the peakvalley timeofuse power price and the environment value, the economic benefit of the gas power generation and the benefit of coalfired power generation were compared. Based on a guess and estimate, the rational grid purchase price of the gas power generation was put forward, which provides a reference for development of the gas power generation industry.
    Study on blockage prevention technology for rotative air preheater of boiler
    WANG Chengliang
    2015, 37(3):  18-21. 
    Asbtract ( 355 )  
    Related Articles | Metrics
    Abstract:There were serious ash deposition and blockage in the rotative air preheater of large thermal power units, and the heat exchange efficiency of the air preheater was reduced, the ventilation resistance was increased. In extreme case, the unit may be compelled to reduce the output. Based on research of the mechanisms of the ash deposition and the blockage of the air preheater, some preventive measures were proposed, which include to optimize the ammonia escape measurement system, to optimize the operation mode of the ammonia injection system, to reform the soot blowing system, to optimize operation mode of the soot blowing system, to optimize operation mode of steam air heater, to adopt corrosionresistant material for the lowtemperature heating surface and so on. The safe and economical operation of the unit was ensured.
    Influence of working condition variation of air cooling system on the turbine output power of 600MW unit
    YU Yao1, WANG Li1, ZHANG Yijiang1, GUO Minchen2, LI Meibao2
    2015, 37(3):  22-25. 
    Asbtract ( 305 )  
    Related Articles | Metrics
    Abstract:The variation of working condition of aircooling system in direct aircooling unit can impact on the exhaust steam pressure and then impact on the unit output power. According to the structure parameters and the operation parameters of the 600MW supercritical direct aircooled unit of a power plant, using the ηNTU method, a mathematic model of aircooling system working condition variation analysis was established. The variation rules of the exhaust steam pressure depending on the inlet air temperature, the exhaust steam heat load and the face air velocity were analyzed respectively. The influences of above factors on the unit output power were analyzed too. According to the influencing rules, the adjustment strategy of the speed and the air volume of the air fan was proposed, which provides a theoretical reference for improving the operation efficiency of the aircooled unit.
    Finite element analysis on translation of steel support of induced draft fan in thermal power unit
    SUN Yewen1, CAI Dongsheng2, ZHUANG Haiqing1, XU Zhibo1
    2015, 37(3):  26-28. 
    Asbtract ( 271 )  
    Related Articles | Metrics
    Abstract:The strength and rigidity finite element analysis for induced draft fan support translation project of the thermal power unit of Guodian Changzhou Thermal Power Plant was carried out, and multiple schemes and multiple conditions were considered in the analysis. The result in this paper provides a theoretical basis for induced draft fan support translation project. The practice verifies that using the translation scheme of this paper, the construction period can be shortened effectively, and the investment can be reduced.
    Identification method of address overlap of IO modules in DCS process control station
    WU Shenghua, TIAN Haibo, WANG Danlin
    2015, 37(3):  29-30. 
    Asbtract ( 308 )  
    Related Articles | Metrics
    Abstract:A practical circuit was introduced, which can be used to monitor the address overlap error of IO modules in distributed control system (DCS) process control station. The circuit principle was analyzed and verified by experiment. The verification result shows that the operation effect of the circuit is favorable.
    Reformation of multistage water seal device for return water of feed pump sealing water
    HONG Li, WANG Xiaowen
    2015, 37(3):  31-33. 
    Asbtract ( 315 )  
    Related Articles | Metrics
    Abstract:The working principle of multistage water seal device for return water of the turbofeed pump sealing water in the 1000MW supercritical unit of Huilai Power Plant was introduced. The problems existing in design, installation and operation of the multistage water seal device were analyzed. A feasible reform scheme is developed and implemented. The longstanding problem of return water recovery of feed pump sealing water was solved.
    Analysis on reasons of lowering of condenser vacuum degree and diagnosis method
    WANG Gang
    2015, 37(3):  34-37. 
    Asbtract ( 328 )  
    Related Articles | Metrics
    Abstract:The parameters reflecting the condenser operation conditions were introduced. The influencing factors, which cause the condenser vacuum degree to lower, were analyzed, and the diagnosis basis of the factors was explained. The diagnosis method of vacuum degree lowering in normal unit operation was illustrated by practical example, and the concepts of extreme vacuum degree and optimal vacuum degree were put forward. The results in this paper can be used as reference for economical operation of steam turbine unit.
    Analysis on economic benefit of reformation of permanent magnet speed controller of closed water pump in a power plant
    ZHAO Yong1, ZHANG Chunjie1, WANG Gang1, YANG Jinfa1, ZHOU Liping2, LI Wenwu3
    2015, 37(3):  38-41. 
    Asbtract ( 365 )  
    Related Articles | Metrics
    Abstract:The flow and the pressure of the closed water pump are usually adjusted by valve, but this causes large amount of energy waste. The permanent magnetic speed control and the variable frequency speed control are oftenused water pump speed control technologies, and the energy conservation effects of the two methods are roughly equal. Considering from the angle of longtime operation, the economic benefit of the permanent magnetic speed controller reformation is lager than the frequency converter, and the system reliability can be improved. So, in energysaving speedcontrol reformation of the closed water pump in Huadian International Laizhou Power Plant, the permanent magnetic speed controller was selected to control of the flow and the pressure of the pump and to reduce the energy consumption. After the reformation, the closed water pump operated more stably, the power consumption was reduced obviously, and the expected effect was achieved. 
    Features of transition section arrangement of tubular belt conveyer
    WANG Huijun
    2015, 37(3):  42-43. 
    Asbtract ( 407 )  
    Related Articles | Metrics
    Abstract:The transition section is an important part of the tubular belt conveyer. General arrangement of the transition section of the tubular belt conveyer was introduced. The structural style and the control points of the tubular belt conveyer were analyzed. After the transition section of the tubular belt conveyer was optimized, the reliability of the tubular belt conveyer was improved.
    Features of capacity air dampers with multipleblade and single blade and operation analysis
    LI Youxin1, ZHANG Yingshuai2, LI Chengshuai1
    2015, 37(3):  44-46. 
    Asbtract ( 263 )  
    Related Articles | Metrics
    Abstract:The control features of air damper of doubleended coal mill were introduced. Under cold stat, the test of the damper opening and air flow test for the multipleblade air damper and the single blade air damper were carried out. The air flow features of the two air dampers and their influences on hot state operation were compared. Some targeted suggestions were given.
    Cleaning methods of circulating water system of indirect aircooled unit
    GAO Yun, CHEN Yunfeng, LIU Lei, YUAN Long
    2015, 37(3):  47-48. 
    Asbtract ( 301 )  
    Related Articles | Metrics
    Abstract:The indirect aircooling tower is more and more widely used in power plant cooling systems. Before the unit is put into operation, the circulating water tank and piping system must be cleaned, and there is not relevant specification on this yet. Combining with engineering practice, taking a 660MW indirect aircooled unit as example, the cleaning methods of the circulating water pipes and tanks of indirect aircooling system were expounded, which can be used as reference for indirect aircooling system in construction and debugging of circulating water system.
    Application of low temperature economizer on 30MW unit
    QI Linhu1, HUANG Xinyuan2, GUO Feng1
    2015, 37(3):  49-51. 
    Asbtract ( 314 )  
    Related Articles | Metrics
    Abstract:In a 30MW thermal power plant of China Huaneng Group, boilers’ flue gas temperature is overhigh, undermining boilers and electric dust collector efficiency. By installing low temperature fuel economizer body between the air preheater s outlet and the precipitator’s intake, and heating the drain tank with boiler waste heat to replenish water, flue gas temperature around the precipitator intake can be reduced, so can the unit economy and dust collector efficiency. After the application of system, flue temperature around the precipitator inlet has been successfully maintained between 90~95℃, and precipitator efficiency greatly improved.
    Calculation of length of thermal insulating pipeline for steam pressure measurement
    ZHOU Xiaofeng, PENG Bin
    2015, 37(3):  52-53. 
    Asbtract ( 349 )  
    Related Articles | Metrics
    Abstract:How to ensure the thermal insulating pipeline for steam pressure measurement without heat tracing to do not freeze in lowtemperature environment was researched. Using the Fourier heat conducting formula, the length of thermal insulating pipeline for steam pressure measurement was calculated. The heat transmits along the sampling pipe in the pipe axial direction. At the same time, the heat radiates out through the heat insulating layer in the radial direction, which causes the temperature of the sampling pipe to lower gradually. The heat released by temperature reducing of the sampling pipeline of the steam pressure transducer is equal to the heat radiated out through the heat insulating layer. Due to that the outdoor steam pressure measurement is widely used in project construction, to adopt the heat insulating method to ensure normal operation of the instrument and the pipeline without heat tracing is of greater significance. Obviously, the investment of this method is low, and the work amount of the construction is reduced.
    Analysis and treatment of cracks on hydraulic turbine runner
    LIU Jiawen
    2015, 37(3):  54-55. 
    Asbtract ( 287 )  
    Related Articles | Metrics
    Abstract:The hydraulic turbine runner is important part of the hydraulic turbine. The crack defect on runner blade can influence on safe and stable operation of the hydropower station. The treatment process of the crack on the runner blade of unit No.4 of Guangdong Yudean Liuxihe Power Generation Company Limited was introduced in detail. The actual reasons of the crack were found, and the crack defect was eliminated.
    Quick startup and stop strategy of oneside axial flow primary air fan of power plant
    ZHANG Guobin
    2015, 37(3):  56-57. 
    Asbtract ( 288 )  
    Related Articles | Metrics
    Abstract:The harm of stall fault of axial flow primary air fan was analyzed. The quick startup and stop methods of the axial flow primary air fan were introduced in detail. The influence of the startup and stop operation on the boiler combustion can be reduced to minimun by the methods, and the safety of the unit operation can be ensured.
    Analysis on exceeding standard hydrogen cation conductivity of lowpressure steam in a gassteam combined cycle unit
    WANG Lihong
    2015, 37(3):  58-60. 
    Asbtract ( 298 )  
    Related Articles | Metrics
    Abstract:Taking the Zhengchangzhuang Gasfired Thermal Power project as example, aiming at the fluctuation of steam hydrogen cation conductivity of the gassteam combined cycle unit, the exceeding standard data of hydrogen cation conductivity of lowpressure steam were analyzed. The deaeration conductivity analyzer was installed, and the reasons cause the hydrogen cation conductivity to exceed standard were found. The result in this paper provides effective basis for the equipment governance.
    Analysis on operation features of MPS212 medium speed mill directfired pulverizing system
    WU Jianliang
    2015, 37(3):  61-63. 
    Asbtract ( 322 )  
    Related Articles | Metrics
    Abstract:Combining with practical operation of MPS212 roller mill of Huadian Liuan Power Generation Company Limited, the factors influencing on the mill operation capacity and threatening operational safety of the mill were analyzed. The relevant countermeasures were proposed. The results in this paper can be used as reference for operation of similar equipments.
    Excavation quality control of rockanchored beam of underground powerhouse in Elephant Trunk Hill Hydropower Station
    TANG Xianghua, GONG Rui
    2015, 37(3):  64-65. 
    Asbtract ( 245 )  
    Related Articles | Metrics
    Abstract:The general situation of the underground powerhouse project of Elephant Trunk Hill Hydropower Station and the geologic features were introduced. The quality control measures of the rockanchored beam excavation of the underground powerhouse were expounded. The construction scheme of the rockanchored beam excavation was put forward. According to the bursting test result, the rational parameters were determined. The remained halfhole rate, the flatness and the bodily form of the excavation surface meet the specification and design requirement. The conclusion of the united acceptance inspection is“excellent”.
    Analysis on reasons of jam fault of steam turbine governing system and treatment measures
    DING Huaigao
    2015, 37(3):  66-67. 
    Asbtract ( 482 )  
    Related Articles | Metrics
    Abstract:Some problems, such as sluggish and jam, occurred in the steam turbine governing system. The problems were analyzed, and it was confirmed that there were defects in the front bearing seat angular pin (plate) and the oil return pipe. In unit startup process, the defects can lead the front bearing seat to shift to left front direction, which will cause the rotor to be offcenter, the steam leakage in front steam seal right side to increase, and the heating expansion of the lever and support of the governing valve to be uneven. The sliding key system was adjusted, the equipment hidden danger was eliminated, and the normal operation of the unit was ensured.
    Research on feasibility of applying oilfree ignition system in 600MW coalfired power plant in Vietnam
    JIANG Fangshuai, YU Wenbo
    2015, 37(3):  68-70. 
    Asbtract ( 353 )  
    Related Articles | Metrics
    Abstract:The coal for Duyen Hai II Coalfired Power Plant in Vietnam is higher volatile coal, and the coal supply is relative stable. Based on analysis of the burning characteristics, the burnout characteristics and the slagging characteristics of the coal, the feasibility to apply the plasma ignition system, to cancel the fuel oil system and to construct oilfree coalfired power plant is researched. Based on estimation, after the fuel oil system was cancelled and the plasma ignition system was installed, the cost of one unit during commissioning period can be reduced by 26.5 millions Yuan. 
    Design of temperature control system of extruding machine of honeycomb fashion denitration catalyst
    PANG Xishu
    2015, 37(3):  71-72. 
    Asbtract ( 334 )  
    Related Articles | Metrics
    Abstract:Using the programmable logic controller (PLC) as the control core; applying the fuzzy selfadaptive PID control technology, an independently operating temperature control unit was designed. The honeycomb fashion denitration catalyst extruding machine was divided into four temperature control parts, using four temperature control units, which operate independently and coordinately, the precise temperature control of the extruding machine was realized, and the product quality was improved.
    Analysis on condensate pump motor of energy saving reconstruction
    ZHAO Zhilong
    2015, 37(3):  73-75. 
    Asbtract ( 290 )  
    Related Articles | Metrics
    Abstract:Three energysaving reformation schemes of condensate pump, which are to replace the motor, to reduce the stages of vane wheel of the pump and to install the frequency converter, were analyzed and researched. The analysis result shows that to install frequency converter is the best energysaving scheme for the motor. The principle and the technical indexes of the frequency conversion technology were expounded, and the practical effects and the economic benefit of the frequency conversion technology in motor energysaving reformation were described.