    Study on power smooth control of microgrid based on energy storage system
    SUN Pan1,2, LAI Xiaolu1,2, YUAN Ye1,2, ZHU Huajing1,2, MENG Xianxia1,2, SUN Feng1,2
    2016, 38(10):  1-4. 
    Asbtract ( 262 )  
    Related Articles | Metrics

    Abstract:For the power supply problems of big fluctuation and strong randomicity caused by connecting renewable energies into microgrid, this paper proposes a power smooth control method of microgrid based on energy storage system. This method takes the measured values of battery state of charge (SOC) as feedback and adjusts the time factor of smooth control method, which could effectively avoid the big power fluctuation of microgrid, stabilize the energy storage batteries SOC in the standard range and improve the service life of battery. The effectiveness of this control method is verified by established simulation model.

    600MW direct air cooling unit steel structure small machine indirect cooling tower resistance characteristic simulation
    WANG Lin, YANG Bo, PU Jianguo, GUO Sanhu, LIU Aijun, ZHAO Ruyu, SONG Xiaohui, KANG Jialin
    2016, 38(10):  5-8. 
    Asbtract ( 293 )  
    Related Articles | Metrics

    Abstract:To study steel structure small machine indirect cooling tower resistance character, a power plant’ 600MW direct cooling unit was taken as study object. Using ICEM-CFD and Meshing software to complete the grid division, the use of Fluent software to calculate the model throughout the flow characteristics, by using fluid mechanics formula modeling, resistance factor was calculated by ANSYS. The result indicated that throat position has largest negative pressure and largest air flow. Resistance factor at X column is smaller than at tower body. Bending position has largest resistance factor. Resistance factor at tower body decreases with Reynolds Number increases.

    Design of electrical mimic panel software based on Visual Basic.NET
    LIN Chong, CHEN Hao
    2016, 38(10):  9-12. 
    Asbtract ( 249 )  
    Related Articles | Metrics

    Abstract:For safety reason, a power plant need an electrical primary mimic panel for operating. Existing mimic panel are made from mosaic jointed panel, which are big, expensive and difficult to maintenance. Thus, a selfdeveloped Visual Basic.NET based electric primary mimic panel was raised. The research and develop process and improvement direction was introduced.

    Hydropower station steel WSD690E strength welding study and application
    YANG Chunguo
    2016, 38(10):  13-16. 
    Asbtract ( 235 )  
    Related Articles | Metrics

    Abstract:By analyzing Jiangxi Hongping Pumped Storage Power Station 800MPa grade steel application, this paper introduced the welding process and performance of domestic 800MPa grade high strength pressure while manufacturing. Through the existing problems, transverse crack causes were analyzed. Solution was provided.

    Circulating fluidized bed boiler blended combusting high calcium coal gangue desulfurization performance test
    REN Qingjie1, NIU Yongjun2
    2016, 38(10):  17-19. 
    Asbtract ( 225 )  
    Related Articles | Metrics

    Abstract:The test of circulating fluidized bed boiler to blend firing different kind of coal or different kind of coal gangue was introduced. The result indicated that selfdesulfurizing performance is obviously different while blending gangue with different calcium content, higher gangue calcium content, better selfdesulfurizing performance. To blend firing high calcium content gangue will remarkably increase boiler selfdesulfurizing performance. For power plant firing high calcium content and low sulphur content coal, to blend high calcium content gangue will increase overall desulfurization efficiency and reduce SO2 emission.

    Automatic generation control optimization of gassteam combined circulating generation unit
    WANG Jiqiang, LIU Yafeng
    2016, 38(10):  20-21. 
    Asbtract ( 237 )  
    Related Articles | Metrics

    Abstract:Specific requirements to regulation performance of automatic generation control(AGC) of power unit are proposed by the “two rules” of North China Grid Company Limited. For the problems of low load change rate and low load response speed of AGC existed in a certain F class twoonone gassteam combined circulating generation unit, a proportion integration differentiation (PID) control of variable parameters is added in the power control circuit of steam turbine, and a threshold method is adopted in the power and speed limiting circuit of AGC, which improved the load change rate and load response speed of steam turbine unit. After that, it meets the examination requirements of AGC under the premise of guarantee the safe and stable operation of unit.

    Application of the system of low temperature economizer with steamair heater on 300MW power unit
    QI Linhu1, HUANG Xinyuan2, LIU Hongying1
    2016, 38(10):  22-24. 
    Asbtract ( 315 )  
    Related Articles | Metrics

    Abstract:For a certain 300MW power unit, the designed system of low temperature economizer with steamair heater could realize the combining waste heat utilization of turbine and boiler, which recover waste heat of flue gas to heat condensation water of steam turbine and cold air at boiler side. After the system put into operation, the boiler thermal efficiency and the circulating heat efficiency are both improved at the meantime, and the full load power generation coal consumption is reduced to 3.02g/(kW·h). Besides, the system also could reduce the lowtemperature corrosion at the cold side and ash blocking of air preheater, control the pressure drop at flue gas side of air preheater, and improve the electrostatic precipitator efficiency. At the end of this paper, the countermeasures for existing problems in the system operation are proposed.

    Implementation of a kind of boiler economizer automatic air exhausting device
    SHI Lei
    2016, 38(10):  25-27. 
    Asbtract ( 253 )  
    Related Articles | Metrics

    Abstract:This paper introduced a kind of boiler economizer automatic air exhausting device, which consists of measuring gauge, remote valve and control device. This device archived to automatically exhaust air from boiler economizer, and will increase the atomization level of whole unit, reduce personal, and save energy.

    Bangladesh Bibiyana Power Station gas steam combined cycle pipe blowing process analysis
    MA Chengjiu1, LI Peng2, WANG Guofeng2
    2016, 38(10):  28-30. 
    Asbtract ( 228 )  
    Related Articles | Metrics

    Abstract:Before the first start and first pipe blowing of waste heat boiler, by adjusting the angle of inlet guide vane (IGV) of gas turbine, the boiler temperature archived 370℃. The air source for pipe blowing was steam produced by boiler itself. Stablereduce pressure combined procedure was implemented on boiler overheater, reheater and high, middle and low pressure steam pipeline. This paper specifically introduced the pipe blowing plan, process and problems.

    Application of sleeve type flowmeter in technical water supply system of hydropower plant
    LI Shizhao, LI Tao
    2016, 38(10):  31-32. 
    Asbtract ( 220 )  
    Related Articles | Metrics
    Abstract:For the technical water supply system of power unit in Yunan Huadian Ludila Hydropower Company Limited, a large number of plugin flowmeters are allocated. And the success rate of unit automatic start up is decreased because of the single function, unstable quality and large operation maintenance workload of plugin flowmeters. Through analysis and demonstration, some measurements are adopted to ensure the safe and stable operation of generating unit. The first one is removing unnecessary flowmeters, the second one is replacing the plugin flowmeters by sleevetype flowmeters, which have the advantages of high response sensitivity, high measurement accuracy, good stability and simple installation technology, and the last one is simplifying and optimizing the operation success conditions of technical water supply of power unit, which could shorten the startup time of hydrogenerator unit.
    Research and problem analysis of mobile testing technology at the scene of ammonia escape
    CHENG Jinwu
    2016, 38(10):  33-36. 
    Asbtract ( 272 )  
    Related Articles | Metrics
    Abstract:After the ultra clean emission transformation of coal fired power unit, the amount of ammonia injected of denitrification system and mass concentration of regional ammonia escape were both increased. In order to conduct the ammoniainjected optimization test based on the concentration field of ammonia escape, the regional realtime mass concentration test of ammonia escape is necessary. Combined with a large number of testing experiences, this paper analyzes the problems of the M-NH3 portable ammonia escape analyzer that appeared in the field test, such as the light path correction, weak spectral signal, filter clogging, electrostatic interference, ammonium sulfate deposition, and the pollution of reflection probes and optical components, etc. After that, this paper summarizes the instrument maintenance measures, which improves the accuracy and stability of ammonia escape test.
    Thermal power plant high pressure water supply pipe vibration diagnostic and treatment
    HU Xin, LIU Ming
    2016, 38(10):  37-39. 
    Asbtract ( 249 )  
    Related Articles | Metrics
    Abstract:Based on the incident of a power plant’s high pressure water supply pipe vibration, by study vibration formula, combined with macroscopic observe, vibration test, simulation analysis and other methods, utilizing rigid limit, hydraulic damper and viscous fluid damper, a pipe vibration control method was established. Which could be referred for thermal power plant pipe vibration treatment.
    Treatment to increase 1050MW unit steam water SiO2 mass concentration test analysis accuracy
    PAN Lina
    2016, 38(10):  40-43. 
    Asbtract ( 222 )  
    Related Articles | Metrics
    Abstract:Ultrasupercritical requires high quality water vapor.SiO2 contains is very low. The tolerance of existing spectrophotometry method to measure SiO2 content is very big. So that, it is difficult to monitor the varying of SiO2 content. Take a 1050MW ultracritical onethrough unit as example, this paper examined the tolerance causes from drug, method, environment and instrument. Test operation and procedure was improved. SiO2 mass concentration accuracy was significantly increased.
    Power plant coal bunker dust cause analysis
    YANG Beibei, MA Ruitao
    2016, 38(10):  44-46. 
    Asbtract ( 262 )  
    Related Articles | Metrics
    Abstract:This paper introduced the structure of coal bunker and cola handling system operation of Huadian Xinxiang Power Plant Company Limited. Dust causes were comprehensively analyzed. Position, form and mass concentration of dust was determined. Which are reliable basis for dust treatment and working environment improvement.
    Reason analysis of coal storage sliding of ringtype coal feeder silo and its preventive measures
    LIN Maohui
    2016, 38(10):  47-48. 
    Asbtract ( 236 )  
    Related Articles | Metrics
    Abstract:For a ringtype coal feeder, which is widely used in coal storage silo system, its design should be optimized to avoid silo sliding under the condition of ensuring the stable operation and output of equipment. This paper analyzes the reason of coal storage sliding of ringtype coal feeder silo, and proposes a solution of adding wearresisting plate on the edge of coal bearing plate for the purpose of guaranteeing the depositing angle at falling point is less than the repose angle of coal.
    Gas fired power plant TCA pipeline inner wall corrosion causes analysis and control measures
    LI Hui
    2016, 38(10):  49-50. 
    Asbtract ( 223 )  
    Related Articles | Metrics
    Abstract:Gas fired power plant flue gas and air system and TCA cooling air system pipeline (TCA pipeline for short) runs was brief introduced. The problem of TCA pipeline inner wall corrosion was indicated. This paper emphasized the corrosion causes and provided improvement suggestions.
    Cooling tower economical comparison of steel mixed structure and GRP structre
    YAN Lu, ZHOU Zhengyi
    2016, 38(10):  51-52. 
    Asbtract ( 237 )  
    Related Articles | Metrics
    Abstract:By studying power plant steel mixed structure and GRP (glass fiber reinforced plastic) structure draft cooling tower, from the viewpoint of construction, comparison of construction term, maintenance, investment capital was made. And the author claimed that GRP structure take advantage from concrete structure, economically and technically, which could be widespread.
    Innovative application of security risk level control in engineering management of coal fired power plant
    ZENG Qinghua1, SU Rongyu2, YANG Zailin1, HUA Wei2, CAO Tong2
    2016, 38(10):  53-56. 
    Asbtract ( 230 )  
    Related Articles | Metrics
    Abstract:Taking the Guizhou Huadian Tongzi Power Generation Company Limited as an example, this paper introduced the innovative application of security risk level control in engineering management of coalfired power plant. Detailed described the security risk level control from five aspects: background, basic thoughts, key links, specific measures and operating effects, and analyzed the security risk levels of coalfired power project at different construction stages and different areas. After that, it precontrolled the security risk using the total plane visualized security risk analysis method and strengthened the process control, which ensured the realization of construction security for a long period.
    Shiliquan Power Plant new environmental index surveillance and management system and implementation effect analysis
    PENG Yuangang
    2016, 38(10):  57-59. 
    Asbtract ( 225 )  
    Related Articles | Metrics
    Abstract:Since May 2014, with a series of environmental laws and regulations, policy implemented, control of pollutants became a main task for power plants. With deepening of the power system, the power generation enterprise profits decreased, efforts to reduce costs become the primary task of for internal management. Huadian Power International Corporation Shiliquan Power Plant established and implemented the new “green energy consumption index” and rewards and punishments, ensured the safe and stable operation of the environmental protection facilities .Annual pollutant emissiononstandard rate up to 99.97%. Environmental protection energy consumption is 10% lower than in 2014, created profits of 7.069 5 million yuan, realize the “environmental protection” and “energy saving” win win situation.
    Measures of reducing measurement failure rate of continuous emission monitoring system for selective catalytic reduction denitrification flue gas
    QI Shanshan
    2016, 38(10):  60-62. 
    Asbtract ( 211 )  
    References | Related Articles | Metrics
    Abstract:At the initial operation stage of continuous emission monitoring system (CEMS) for selective catalytic reduction (SCR) denitrification flue gas in Anhui Huadian Suzhou Power Generation Company Limited, measurement faults occurred frequently, which affected the reliability of online flue gas monitoring, made the operation adjustment difficult and increased the maintenance work amounts. This paper analyzed the measuring principles of CEMS, summarized the common faults and their treatment measures of CEMS, and proposed some prevention measures. After adopting a series of measures, the measurement failure rates of NOx and NH3 of CEMS were effectively decreased.
    Hubei Xisaishan Power Plant flue gas denitration technology analysis
    DENG Huipeng
    2016, 38(10):  63-65. 
    Asbtract ( 222 )  
    Related Articles | Metrics
    Abstract:Denitration system equipment and technology features of Hubei Xisaishan Power Plant first stage (2×330MW) and second (2×380MW) was introduced. The experience was summarized. Which could be referred by similar project.
    Energy conservation and low cost operation measures for thermal power plant
    TAO Zaisu
    2016, 38(10):  66-68. 
    Asbtract ( 275 )  
    Related Articles | Metrics
    Abstract:According to the practical running experience of Huadian Baiyinhua Jinshan Power Generation establishing conservationminded company, this paper introduced a series of practical measures on boiler parameters control, combustion adjustment, lowering turbine back pressure, increasing feedwater temperature and saving auxiliary power. Thus the plant achieved the aim of energysaving and costreducing.
     Parallel deaerator operation energy saving analysis and technology improvement
    BAI Feng
    2016, 38(10):  69-72. 
    Asbtract ( 274 )  
    Related Articles | Metrics
    Abstract:Due to large deaerator makeup water requires, large heat steam consumption, high cost and wasting residue water while maintenance, technology improvement has been done. The utilization of communicating vessel was proposed. Method to reduce waste of deaerator tank residue water before maintenance was indicated. Which will effectively reduce deaerator operational cost. At the same time, production cost will be reduced, and realized energy saving and cost decreasing and benefit increasing.
    Construction of multienergy complementary integrated energy supply system for sewage treatment plant and its economic analysis
    SUN Zhenyu, SHEN Mingzhong, CHEN Beiyang, WANG Jianhua
    2016, 38(10):  73-76. 
    Asbtract ( 315 )  
    Related Articles | Metrics
    Abstract:Under the pressures of energy conservation and emissions reduction, the utilization of renewable energy becomes an important means to reduce cost and improve efficiency of an enterprise. Combining with the local advantages of rich solar energy resources, low shielding rate of buildings and rich sewage heat sources, the sewage treatment plant builds distributed photovoltaic system and installs sewage source heat pumps in plant, which constructs a multienergy complementary integrated energy supply system. In the system, the average treatment capacity of sewage treatment plant is 40000m3, which consumes a huge amount of electricity. The photovoltaic power generation system, whose average annual electricity production is 1059018kW·h, average annual equivalent utilization hours are 1170 and selfuse rate is 94%, could provide sufficient electricity for sewage treatment system and sewage source heat pumps, and the remaining electricity could be sold online, which would save 1190000 yuan for the plant in total. In addition, compared with the air conditioner system, the sewage source heat pumps also could save electricity 150763kW·h. In conclusion, the multienergy complementary integrated energy supply system could save standard coal 387.1t and reduce emissions of CO2 and other pollutions 483.6t year, and which is helpful to improve the resource utilization rate, promote energy conservation and emissions reduction and reduce the operation costs.